Parameter | |||
Model No. | K18C-UP600D24+12 | ||
Output | Output voltage | CH1 | CH2 |
+24VDC | +12VDC | ||
Rated current | 24A | 2A | |
Rated power | 576W | 24W | |
Ripple & noise | 350mVp-p | 200mVp-p | |
Voltage adjustable range | ±5% | / | |
Output accuracy | ±1% | ±3% | |
Line regulation | ±0.5% | ±0.5% | |
Load regulation | ±1 % | ±3% | |
Cross adjustment rate | ±3 % | ±17 % | |
Set up,rise,keep up time | 300ms,20ms,12ms | ||
Input | Input voltage range | 90V~264V AC | |
Input current | 3.8A/230Vac 7.6A@115Vac | ||
Frequency range | 50~60Hz` | ||
Efficiency | 92% when the input voltage is 230VAC | ||
Power factor | PF>0.98/115V orPF>0.95/230V | ||
Inrush current | Cold start 60A/230Vac | ||
Leakage current | <0.5mA@240V | ||
Protection | Overload protection | 105~150% Hiccup protection, automatic recovery | |
Short circuit protection | Deadlocked protection, need to be restored after restart. | ||
Output over-voltage protection | >120% off, locked protection, need to restart after recovery. | ||
Over-temperature protection | TS1 position > 105°C will beprotected, automatic recovery. | ||
Environment | Work temperature,humidity | -20~50℃,10~90% RH,No condensation | |
Storage temperature humidity | -20~85℃,10~95% RH | ||
Temperature drift | ±0.03%/℃(0~50℃) | ||
Vibration | 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES | ||
Safety & EMC standards | Safety standards | GB4943 EN60950 EN62368-1 | |
Withstand voltage | I/P-O/P:3KV; I/P-FG:1.8KV;O/P-FG:0.6KV AC 1min. | ||
Insulation resistance | I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms | ||
EMC standards | EN55032 Class B | ||
Others | MTBF | >50K hrs | |
Dimension | 168*82*41mm | ||

Hot Tags: 600w 24v 12v dc converter, China, manufacturers, suppliers, factory, customized, buy, made in China, 24V Dual Power Supply, 12V 8A Power Supply Open, 150 Watt Power Supply, Dc36v 1200w Power Supply, moving head lights open frame psu, switching power supply 100 240v