Specification | ||
Item NO. | K19H-UP1200S24 V2 | |
Output | Output voltage | +24V |
Rated current | 50A | |
Current range | 0-50A | |
Rated power | 1200W | |
Ripple | 240mVp-p | |
Output adjustable range | ±5% | |
Output accuracy | ±1% | |
Line regulation | ±0.5% | |
Load regulation | ±0.5% | |
Set-up,rise,hold up time | 500ms, 30ms,5ms/115VAC 300ms, 30ms,10ms/230VAC | |
Input | Input voltage | 88~264V AC |
Input current | 12A/115V 6A/230V | |
Frequency | 47~63Hz | |
Efficiency | 92% @230V,88% @115V | |
Inrush current | 40A@230V | |
Leakage current | <3.5mA@240V | |
Power factor | >0.9@220V,>0.95@110V | |
Protection | Overload protection | 105~150% protection, automatic recovery |
Short circuit protection | Automatic recovery | |
Output overvoltage protection | 27-33V | |
Over temperature protection | >105 ° C, the output is off, and the recovery is automatic. | |
Others | Auxiliary power | Provide 12V 0.2A auxiliary voltage output |
Standby function | At the RC terminal, add a high level, turn off the CH1 and CH2 outputs. | |
Environment | Working temperature, humidity | -20~+60℃,10~90% RH,No condensation |
Storage temperature, humidity | -40~85℃,10~95% RH | |
Safety&EMC standards | Safety standards | GB4943 EN62368 |
Withstand voltage | I/P-O/P: 3KV,I/P-FG:1.5KV;O/P-FG:0.5KV DC 1min. | |
Insulation resistance | I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms | |
EMC standard | EN55032 CLASS B,EN61000-3-2 | |
Others | Dimension | 180*82*48mm |
weight | 1.2Kg | |

Q1:Why did the power supply shuts down during operation and after turning it off, I can restart the power supply again?
A1:In general there are two circumstances that will cause the power supply to shut down. The first one is the activation of the over-load-protection (OLP). To deal with this situation, we suggest increasing the rating of the output power or modifying the OLP point. The second one is the activation of over-temperature protection (OTP) when the internal temperature reaches the pre-set value. All of these conditions will let the S.P.S. enter protection mode and shut down. After these conditions are removed, the S.P.S. will be back to normal.
Q2:What are the protection forms of overload/over current?
(1)When current drawn exceeds the rating of the PSU, the protection circuit will be triggered to protect the unit against overload/overcurrent.
Protections of overload/overcurrent can be divided into several forms:
(1)FOLDBACK CURRENT LIMITING
Output current decreases about 20% of rated current, shown as curve (a) in the figure below.
(2)CONSTANT CURRENT LIMITING
Output current remains at a constant level and within the specified range while the output voltage drops to a lower level, shown as curve (b) in the figure below.
(3)OVER POWER LIMITING
Output power remains constant. As output load increases, output voltage decreases in proportion, shown as curve (c) in the figure below.
(4)HICCUP CURRENT LIMITING
Output voltage and current keep pulsing ON and OFF repeatedly when protection is activated. The unit automatically recovers when faulty condition is removed.